| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Load - Max Switching | Coil Current | Coil Type | Features | Termination Style | Seal Rating | Coil Insulation | Must Operate Voltage | Must Release Voltage | Operate Time | Release Time | Operating Temperature | Contact Material | Relay Type | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
8501CDO21V53POWER RELAY, TYPE C, 20A RESISTI |
2,545 | - |
|
Datasheet | Square D 8501C | Box | Obsolete | Chassis Mount | 24VDC | SPST-NO (1 Form A) | 20 A | 500VDC - Max | 10000VA | - | Non Latching | - | Screw Terminal | - | - | - | - | - | - | -30°C ~ 60°C | - | General Purpose | - | - |
|
8501XO20V02RELAY 600VAC 10AMP NEMA +OPTIONS |
2,682 | - |
|
Datasheet | Square D 8501X | Box | Active | Chassis Mount | 120VAC | DPST-NO (2 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 102 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO30V02RELAY 600VAC 10AMP NEMA +OPTIONS |
4,918 | - |
|
Datasheet | Square D 8501X | Box | Active | Socketable | 120VAC | 3PST-NO (3 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 102 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO40V06RELAY 600VAC 10AMP NEMA +OPTIONS |
1,692 | - |
|
Datasheet | Square D 8501X | Box | Active | Chassis Mount | 480VAC | 4PST-NO (4 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 408 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO40V01RELAY 600VAC 10AMP NEMA +OPTIONS |
3,383 | - |
|
Datasheet | Square D 8501X | Box | Active | Socketable | 24VAC | 4PST-NO (4 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 204 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO40V02RELAY 600VAC 10AMP NEMA +OPTIONS |
4,710 | - |
|
Datasheet | Square D 8501X | Box | Active | Chassis Mount | 120VAC | 4PST-NO (4 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 102 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO40V03RELAY 600VAC 10AMP NEMA +OPTIONS |
2,832 | - |
|
Datasheet | Square D 8501X | Box | Active | Socketable | 240VAC | 4PST-NO (4 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 204 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XDO20V53RELAY 600VAC 10AMP NEMA +OPTIONS |
1,473 | - |
|
Datasheet | Square D 8501X | Box | Active | Chassis Mount | 24VDC | DPST-NO (2 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 19.2 VDC | - | 37 ms | 21 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO80V02RELAY 600VAC 10AMP NEMA +OPTIONS |
3,768 | - |
|
Datasheet | Square D 8501X | Box | Active | Chassis Mount | 120VAC | 8PST-NO (8 Form A) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | 102 VAC | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
|
8501XO42V02NEMA CONTROL RELAY, TYPE X, MACH |
1,513 | - |
|
Datasheet | Square D 8501X | Box | Obsolete | Chassis Mount | 120VAC | 6PST-4NO/2NC (4 Form A, 2 Form B) | 10 A | 600VAC - Max | 6000VA | - | Non Latching | - | Screw Terminal | - | - | - | - | 15 ms | 16 ms | -40°C ~ 71°C | - | General Purpose | - | - |
Power Relays, Over 2 Amps FAQ
Common questions about filtering, comparing and sourcing Power Relays, Over 2 Amps components.
How can I narrow the Power Relays, Over 2 Amps selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Power Relays, Over 2 Amps part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.